当前位置:服务支持 >  软件文章 >  ANSYS浇筑混凝土过程模拟方法与技术要点解析

ANSYS浇筑混凝土过程模拟方法与技术要点解析

阅读数 4
点赞 0
article_banner


!大伙看看,有何问题,如何改进?


!100*80*10基岩上浇筑混凝土50*40*10,每三天浇筑1米高(第一天浇完,剩下两天窝工),


!共用一个月时间,分为十层(layer)浇筑,模型、条件均为假设


!建模


/filename,test


/PREP7


BLOCK,,50,,10,,40,


BLOCK,-25,75,-10,0,-20,60


ET,1,70


LSEL,S,,,9,12,1


LESIZE,ALL,,,10


LSEL,S,,,21,24,1


LESIZE,ALL,,,20


LSEL,S,,,2,4,2


LSEL,A,,,5,7,2


LESIZE,ALL,,,10


LSEL,S,,,14,16,2


LSEL,A,,,17,19,2


LESIZE,ALL,,,20


LSEL,S,,,1,3,2


LSEL,A,,,6,8,2


LESIZE,ALL,,,10


LSEL,S,,,13,15,2


LSEL,A,,,18,20,2


LESIZE,ALL,,,5


allsel


MP,DENS,1,2400.0 !混凝土材料


MP,KXX ,1,300.89


MP,C,1,0.94500


MAT,1


VMESH,1


MP,DENS,2,2600.0 !基岩材料


MP,KXX ,2,300.89


MP,C,2,0.94500


MAT,2


VMESH,2


nummrg,all


!热分析


/SOLU


NROPT,FULL !Specifies the Newton-Raphson options in full transient analysis


ESEL,S,MAT,,2 !MAT2 IS 基岩


NSLE,S


IC,all,TEMP,16.4, !加基岩初温


ASEL,S,,,7,9,1


ASEL,A,,,11,12,1


NSLA,S,1


SF,all,HFLUX,0 !加基岩绝热边界条件


NSEL,S,LOC,Y,-0.1,0.1


ASEL,S,,,3


NSLA,U,1


SF,ALL,CONV,2016,20 !加基岩第三边界条件(和空气接触面)


!加初始条件


ALLSEL,ALL


ESEL,U,MAT,,2


NSLE,S


EKILL,ALL !KILL 混凝土


IC,all,TEMP,35, !混凝土浇筑时温度为35度


ANTYPE,TRANSIENT,new !分析类型


!日子的流逝


*DO,LAYER,1,10,1


 !激活第N层单元


 ALLSEL,ALL


 NSEL,S,LOC,Y,(LAYER-1),LAYER !第一层从Y=0~1米,第二层从Y=1~2米,...


 ESLN,S ,1


 EALIVE,ALL


 *DO,DAY,LAYER*3-2,LAYER*3,1 !每三天浇筑一层


 ALLSEL,ALL


 ASEL,S,,,1,2,1


 ASEL,A,,,5,6,1


 NSLA,S,1


 NSEL,R,LOC,Y,0,LAYER


 NSEL,A,LOC,Y,LAYER-0.1,LAYER+0.1


 SF,ALL,CONV,2016,20 !加混凝土第三类对流边界条件


 *DO,LOOP,1,LAYER,1


 ALLSEL,ALL


 NSEL,R,LOC,Y,LOOP-1,LOOP


 ESLN,S,1


 TDAY=DAY-(LOOP-1)*3 !已经完工的天数


 HE00=47880*(TDAY/(0.862+TDAY)-(TDAY-1)/(0.862+TDAY-1))


 BFE,ALL,HGEN, ,HE00 !加水化热


 *ENDDO


 !计算设置


 ALLSE


 TRNOPT,FULL


 LUMPM,0


 TIME,DAY


 AUTOTS,0


 DELTIM,1, , ,1


 KBC,0


 TSRES,ERASE


 OUTRES,ALL,ALL,


 SOLVE


 *ENDDO


 ESEL,S,MAT,,1


 NSLE,S,


 SFEDELE,ALL,ALL,CONV !删对流边界条件


 SFDELE,ALL,CONV


*ENDDO


FINISH



!结构分析


/PREP7


ET,1,SOLID65 !变热单元为结构单元


*DIM,EXX,ARRAY,30 !考虑变化的EX


EXX(1)=0.325E10,0.57778E10,0.78E10,0.94545E10,0.10833E11,0.12E11,0.13E11,0.13867E11,0.14625E11,0.15294E11, 0.15889E11, 0.1642E11 ,0.169E11, 0.17333E11, 0.17727E11, 0.18087E11,0.18417E11,0.1872E11


EXX(19)=0.190E11, 0.19259E11, 0.195E11, 0.19724E11, 0.19933E11, 0.20129E11,0.20312E11, 0.20485E11, 0.20647E11, 0.208E11, 0.20944E11, 0.21081E11


*DO,I,1,30,1 !定义材料,混凝土浇筑完每过一天变一种材料


 MP,DENS,I,2400


 MP,EX,I,EXX(I)


 MP,PRXY,I,0.167


 MP,ALPX,I,0.9E-5


 MP,REFT,I,15


*ENDDO


MP,DENS,31,2600 !定义基岩材料


MP,EX,31,0.20800E+11


MP,PRXY,31,0.167


MP,ALPX,31,0.9E-5


ESEL,S,MAT,,,2


MPCHG,31,ALL, !!变热材料为结构材料


ALLSEL


/SOLU


NROPT,FULL !Specifies the Newton-Raphson options in a full transient analysis


NLGEOM,ON


NSLA,S,,,7,9,1


NSLA,A,,,11,12,1


D,all,ALL !加基岩约束


!KILL THE CONCRETE ELEMENT


ESEL,U,MAT,,1


NSLE,S


EKILL,ALL !KILL 混凝土


*DO,DAY,1,30,1 !随时间改变,变换材料


 *DO,LAYER,1,10


 *IF,DAY,GT,LAYER*3-3,THEN


 NSEL,S,LOC,Y,LAYER-1,LAYER


 ESLN,S,1


 EALIVE,ALL !ACTIVE NEXT LAYER


 MPCHG,DAY-(LAYER-1)*3,ALL, !CHANG MAT


 ALLSEL,ALL


 *ENDIF


 *ENDDO


 ALLSEL,ALL


 ACEL,0,0,-9.8, !GRAVITY LOAD


 LDREAD,TEMP,,,DAY, ,'TEST','rth',' ' !TEMP LOAD Reads results from the results file and applies them as loads.


 CNVTOL,F, ,0.2,2,200, !Sets convergence values for nonlinear analyses.


 TIME,DAY


 AUTOTS,0


 DELTIM,1, , ,1


 KBC,0


 TSRES,ERASE !Defines an array of keytimes at which the time-stepping strategy changes


 OUTRES,ALL,ALL,


 SOLVE


*ENDDO


!1、定义重力集散地是应为正值:ACEL,0,0,9.8


!2、砼单元边长(1*4*5)相差5倍,对计算精度的影响会不会较大?


!3、热单元SOLID70对应的结构单元为SOLID45,改为SOLID65是否合适?


!4、原分析得到的结果与实际情况比较如何?


!5、如何体现气温的变化?


免责声明:本文系网络转载或改编,未找到原创作者,版权归原作者所有。如涉及版权,请联系删

相关文章
QR Code
微信扫一扫,欢迎咨询~

联系我们
武汉格发信息技术有限公司
湖北省武汉市经开区科技园西路6号103孵化器
电话:155-2731-8020 座机:027-59821821
邮件:tanzw@gofarlic.com
Copyright © 2023 Gofarsoft Co.,Ltd. 保留所有权利
遇到许可问题?该如何解决!?
评估许可证实际采购量? 
不清楚软件许可证使用数据? 
收到软件厂商律师函!?  
想要少购买点许可证,节省费用? 
收到软件厂商侵权通告!?  
有正版license,但许可证不够用,需要新购? 
联系方式 155-2731-8020
预留信息,一起解决您的问题
* 姓名:
* 手机:

* 公司名称:

姓名不为空

手机不正确

公司不为空