2023-10-07 22:16:40 RAID_Array 触发 严重 Transition to Critical from less severe---PCIe slot:2
2023-10-07 22:19:36 HDD_F02_Status Drive Slot (Bay) 触发 正常 Rebuild/Remap in progress
2023-10-09 01:20:59 HDD_F02_Status Drive Slot (Bay) 解除 正常 Rebuild/Remap in progress
2023-10-09 01:21:07 RAID_Array add_in_card 触发 正常 Transition to OK---PCIe slot:2
10.7号22:16分报slot 2硬盘故障,紧接着22:19分该位置硬盘开始自动同步。等自动同步完成正常运行几天后又报slot2位置硬盘预故障,需要更换。以后遇到硬盘报错后立即自动rebuilding可取消rebuild直接进行硬盘更换操作,硬盘存在介质性报错。
2023-10-14 07:23:45 HDD_F02_Status Drive Slot (Bay) 触发 轻微 Predictive failure
第二台同样问题:
2023-10-22 10:01:39 RAID_Array Add-in Card 触发 严重 Transition to Critical from less severe---PCIe slot:2---LDDevno :1
2023-10-22 10:04:10 HDD_F09_Status Drive Slot (Bay) 触发 正常 Rebuild/Remap in progress
使用阵列卡工具storcli64查看磁盘介质性错误
#storcli64 /c0/eall/sall show all |grep -e "Error Count" |grep -A 3 -B 3
查看到1号硬盘 Media Error Count 691;
9、11号硬盘Other Error Count 7,根据经验分析Other Error Count与磁盘健康关系更大。9号硬盘 从raid卡日志看到有Command timeout。
#storcli /c0 show events > /tmp/raid-events.log //导出raid卡events日志查看
同步一天多时间没完成,报出9号硬盘故障
11号热备盘顶上开始同步
免责声明:本文系网络转载或改编,未找到原创作者,版权归原作者所有。如涉及版权,请联系删